Are you a factory or a trading company?
We are the original manufacturer with our own production facility. You are welcome to visit our factory.
What after-sales services do you provide?
We provide installation manuals and SOPs, video guidance and online technical support. Overseas engineer support can also be arranged according to project requirements.
What payment methods do you accept?
We accept bank transfer (T/T) and Trade Assurance orders. Final payment terms are confirmed in the quotation or contract.
How can we verify product quality after placing an order?
Before delivery, we provide photos and videos for quality checking. Buyers may also arrange their own inspection or appoint an independent third-party inspection company.
How are our payment and order protected?
We can provide our business license and available certificates for verification. Trade Assurance can also be used for eligible orders to help protect the buyer's payment.
Can we discuss agency or distribution rights for your products?
Yes. We welcome discussions on product agency and distribution rights. We can provide product and technical training, sales support and access to consumable spare parts. Territory and cooperation terms can be confirmed in a formal agreement.
Our Process Advantages
A clear comparison of SUNRUN construction standards and common entry-level market practices.
| Process Area | SUNRUN Standard | Common Market Practice |
|---|---|---|
| 01Frame | Fully galvanized steel with electrostatic powder coating, reinforced lifting heads and a balanced load-bearing frame. | Black steel or partially protected frames; reinforcement and corrosion-protection details are often unclear. |
| 02Profile Density | Closer steel-member spacing provides stronger floor support, better stability and greater resistance to deformation. | Reduced steel sections or wider spacing may lower cost but can increase floor vibration and structural movement. |
| 03Embedded Hinge | Recessed galvanized hinges sit flush with the floor for a smooth surface and a cleaner finished appearance. | Exposed welded hinges may protrude above the floor and leave uneven welds or finishing gaps. |
| 04Roof Waterproofing | A 0.8 mm corrugated steel center roof supports effective drainage and more reliable long-term waterproofing. | Sheet-roof joints often rely on waterproof tape that can age, loosen or create leakage risks. |
| 05Wall Insulation | 75 mm EPS exterior walls and 50 mm interior partitions, with PU, rock-wool and other climate-specific upgrades. | Basic 50–65 mm EPS panels with fewer insulation grades and limited climate-specific options. |
| 06Windows & Glass | Thermal-break aluminum frames with double, triple, Low-E or laminated glazing and customizable sealing systems. | Standard uPVC, aluminum or single-glass systems; profile, hardware and sealing grades may be unspecified. |
| 07Electrical Wiring | Destination-standard circuits, concealed wiring, separated protection and protected folding points, factory tested. | Basic direct wiring with limited protection at folding points and incomplete circuit-sizing details. |
| 08Bottom Insulation | PU spray or EPS insulation with optional graphene floor heating forms an integrated insulation, moisture-control and heating system. | A basic floor substrate or simple EPS filling, often without a complete bottom-insulation or heating system. |
| 09Bathroom Drainage | Concealed pipework with floor slope, drainage speed and joint sealing checked before shipment. | Exposed or basic PVC drainage with limited information on slope, sealing and pre-delivery testing. |
| 10Interior Finish | Bamboo-wood fiber wall and ceiling panels with coordinated trim reduce or eliminate secondary on-site finishing. | Galvanized color-steel interiors and sealant-finished gaps provide a more basic appearance and living comfort. |
Visual Process Comparison
Selected production details from the supplied material and process comparison file.
Frame
Embedded Hinge
Roof Waterproofing
Electrical Wiring
Bottom Insulation
Bathroom Drainage
30ft Expandable House
A spacious 56 m² 30ft expandable container house with a quick-expansion dual-wing design, durable steel frame and flexible one-, two- and three-bedroom layouts. Suitable for residential, accommodation, office and project-site use, with customizable doors, windows, wall panels, insulation, electrical, plumbing and interior finish options for efficient transport and fast on-site assembly.
Specifications shown are for the confirmed 30ft base configuration. Final dimensions, weight and material schedule are verified against the signed production specification.
| Basic Information | |||
|---|---|---|---|
| Product Model | 30ft Double-Wing Expandable Container House | ||
| Expanded Dimensions | L9000 × W6220 × H2480 mm | Floor Area | 56 m² |
| Internal Dimensions | L8420 × W6060 × H2200 mm | Approx. Weight | Approx. 4.55 metric tons (4,550 kg) |
| Folded Dimensions | L9000 × W2200 × H2480 mm | Recommended Electrical Capacity | 12 kW |
| Framework Structure | |||
| System | Component | Specification | |
| Main Frame Fully Galvanized |
Upper Main Beam | 80 × 140 × 3.0 mm square tube | |
| Upper Cross Beam | 2.0 mm bent steel component | ||
| Lower Main Beam | 80 × 140 × 3.0 mm square tube | ||
| Lower Cross Beam | 2.0 mm bent steel component | ||
| Upright and Lifting Head | 2.0 mm bent steel component with 6 mm inner reinforcement plate | ||
| Side Frame Fully Galvanized |
Top Frame | 40 × 80 × 1.5 mm P-shaped tube | |
| 40 × 80 × 1.5 mm square tube | |||
| 2.0 mm bent steel component | |||
| Bottom Frame | 60 × 80 × 1.5 mm square tube | ||
| 80 × 80 × 1.5 mm square tube | |||
| Side Wall Frame | 70 × 80 × 1.2 mm rectangular tube and 40 × 80 mm P-shaped tube | ||
| Folding Hinge | 13 mm galvanized hinge | ||
| Frame Protective Coating | Spray Coating | Electrostatic powder coating | |
| Roof System | |||
| System | Component | Specification | |
| Roof | External Central Roof | 1 mm corrugated steel sheet (integral welded) | |
| Internal Roof Slab | 50 mm EPS sandwich panel | ||
| Internal Ceiling Panel | 50 mm EPS sandwich panel | ||
| Wall Panels | |||
| System | Component | Specification | |
| Wall Panels | External Wall Panels | 75 mm EPS sandwich panel | |
| Internal Partition Panels | 50 mm EPS sandwich panel | ||
| Flooring | |||
| System | Component | Specification | |
| Flooring System | Central Flooring | 18 mm fire-resistant magnesium oxide board | |
| Side Flooring | 18 mm fire-resistant magnesium oxide board | ||
| PVC Flooring | 2.0 mm PVC flooring | ||
| Electrical System | |||
| System | Component | Specification | |
| Electrical | Circuit Breaker System | 1 × 63 A earth-leakage circuit breaker and 4 circuit breakers | |
| Lighting | LED round ceiling lights | ||
| Sockets | As required | ||
| Light Switches | Double-gang and single-gang switches | ||
| Wiring | Incoming 6 mm²; water heater 6 mm²; kitchen sockets 4 mm²; air-conditioner sockets 4 mm²; standard sockets 2.5 mm²; lighting 1.5 mm² | ||
Product Overview
Quick-Expansion Design
The 30-foot dual-wing structure expands rapidly to both sides, offering greater usable space than standard containers.
Robust Steel Frame Structure
Built with durable steel construction, it features excellent stability, high strength, and a long service life, suitable for various site conditions.
Flexible Interior Layout
Ideal for multiple uses including bedrooms, offices, living rooms, kitchens, bathrooms, temporary accommodations, or mobile workspaces.
Easy Transportation and Installation
Its compact 30-foot folded profile facilitates convenient sea and land transport; once on-site, quick assembly saves labor and time costs.
Customizable Options
Doors, windows, wall panels, flooring, electrical and plumbing systems, colors, and interior layouts can all be customized according to project requirements.
Floor Plans
Open-plan living space with one bathroom
Bedrooms: Open-plan / Studio
Floor Area: Approx. 56 m²
1-2 people
Spacious open-plan layout with an independent bathroom and flexible living area. The approximately 56 m² interior provides ample space for sleeping, living and dining functions, making it suitable for 1–2 occupants. The open space can also be arranged according to different residential or project requirements.
Two bedrooms, one living room and one bathroom
2 bedrooms
Approx. 56 m²
3–4 people
Two-bedroom layout with two independent bedrooms, a spacious living area and one bathroom. The approximately 56 m² interior provides a practical balance between private sleeping areas and shared living space, suitable for family living, staff accommodation or long-term residential use.
Three bedrooms, one living room, one kitchen and one bathroom
3 bedrooms
Approx. 56 m²
4–6 people
Three-bedroom layout featuring three independent bedrooms, a shared living area, a practical kitchen space and one bathroom. With approximately 56 m² of floor area, this configuration provides good privacy and efficient use of space, making it suitable for families, staff accommodation and long-term residential projects.
Technical Specifications
Dimensions shown are for the confirmed 30ft base configuration. Final dimensions and weight are verified against the signed production specification.
Expanded Dimensions
L9000*W6220*H2480
Internal Dimensions
L8420*W6060*H2200
Folded Dimensions
L9000*W2200*H2480
Floor Area
56 m²
Approx. Weight
Approx. 4.55 metric tons (4,550 kg)
Recommended Electrical Capacity
12 kW
Factory-prefabricated structural and enclosure system. Final material schedule is confirmed before production.
Main Frame
Upper main beam: 80*140*3.0mm square tube; lower main beam: 80*140*3.0mm square tube square tube; cross beams: 2.0 mm bent steel components; uprights and lifting heads: 2.0 mm bent steel components with 6 mm inner reinforcement plates.
Side Frame
Top frame: 40*80*1.5mm P-shaped tube; bottom frame: 60×80×1.5 mm and 80×80×1.5 mm square tubes; 2.0 mm bent steel components; 13 mm galvanized folding hinges.
Protective Coating
Electrostatic powder coating.
Roof System
1mm corrugated steel sheet (integral welded), 50 mm EPS sandwich panel
Wall Panels
75 mm EPS sandwich panel for external walls; 50 mm EPS sandwich panel for internal partitions.
Flooring
18 mm fire-resistant magnesium oxide board for central and side flooring, finished with 2.0 mm PVC flooring.
Designed for efficient transportation and rapid on-site installation. The expandable structure provides a spacious open-plan interior with reliable structural, weather and acoustic performance.
Installation Time
Less than 1 hour after site preparation
Wind Resistance
Grade 3 hurricane resistance
Sound Insulation
Up to 60 dB
Snow Load
Up to 1.0 kN/m²
Design Service Life
More than 50 years with proper installation and maintenance
Utility Connections
Electrical and plumbing systems can be prepared for on-site connection
Configuration & Applications
Galvanized coated frame
75 mm EPS exterior wall panels
50 mm EPS internal partitions
40 mm PU floor insulation in central and wing areas
Finished interior walls and ceiling
Basic electrical and plumbing preparation
PU wall insulation
Graphene electric floor heating
Thermal-break aluminum windows
Double, Low-E or laminated glazing
Customized kitchen and bathroom
Solar, inverter and battery system
Permanent or seasonal residence
Farm and rural housing
Resort and scenic-area accommodation
Worker or project-site accommodation
Guest house or rental unit
Remote-area living
Packaging & Shipping
Packaging Method
Protective factory packing for container transport
Folded Dimensions
5900 × 700 × 2480 mm
Shipment Weight
Approx. 4.55 metric tons (4,550 kg); confirm before shipment
Unloading Equipment
Crane or suitable lifting equipment selected for site conditions
Installation Support
Installation drawings, video guidance and remote technical support can be provided. Site foundation, lifting and local utility connection remain project-specific.
Logistics Notes
Container loading and route planning are confirmed from the final product configuration, destination and port requirements.
Frequently Asked Questions
Can the 30ft layout be customized?
Yes. Room arrangement, doors, windows, kitchen, bathroom, electrical and plumbing positions can be adjusted within the structural design limits.
Can the insulation be upgraded for cold climates?
Yes. PU insulation, thermal-break aluminum windows, insulated or Low-E glazing and electric floor heating can be specified for the project climate.
Is the house delivered finished?
The selected configuration can be factory-finished with interior wall and ceiling panels, electrical preparation, plumbing, kitchen and bathroom components to reduce on-site work.
Can SUNRUN provide a solar power system?
Yes. Solar panels, hybrid inverter, battery storage and project-specific cable packages can be integrated after the electrical load and destination requirements are confirmed.
How is the unit transported and installed?
The house is folded for container transport, unloaded with suitable lifting equipment and expanded on the prepared foundation. Final logistics and lifting plans are confirmed per project.
What information is needed for a quotation?
Please provide destination, quantity, intended use, preferred layout, insulation level, electrical standard, interior finish and required optional systems.
Explore the Range
Related Product Families
Use these collection links to compare other modular building formats and open their available product pages.

Expandable Homes
More usable interior space with compact transport dimensions.
Open collection →
Folding Container Houses
Fast-deploying structures for temporary and project-based use.
Open collection →
Modular Project Buildings
Modular building blocks for offices, camps and accommodation.
Open collection →
Apple Cabin Houses
Contemporary compact cabins for hospitality and private use.
Open collection →Collection pages serve as the index for current and future product detail pages.
Configure the 30ft for Your Project
Tell us the destination, quantity, use, climate and required configuration. SUNRUN will prepare a matched technical proposal and quotation.


